[titles text=”Q2FkYSUyMHVubyUyMGNvbiUyMDQ4VSUyMGRlJTIwZXNwYWNpbyUyMGRlJTIwcmFjayUyMGVzdCVDMyVBMW5kYXIuJTIwTG9zJTIwbSVDMyVCM2R1bG9zJTIwZGUlMjBlbmZyaWFtaWVudG8lMjBkZSUyMGFpcmUlMjB5JTIwbCVDMyVBRHF1aWRvJTIwc2UlMjBwdWVkZW4lMjBjb25maWd1cmFyJTIwZW4lMjBmdW5jaSVDMyVCM24lMjBkZSUyMGxhJTIwY2FyZ2ElMjBkZSUyMFRJJTIweSUyMGxhJTIwbmVjZXNpZGFkJTIwZGUlMjB1bmElMjBvcGVyYWNpJUMzJUIzbiUyMHJlZHVuZGFudGUuJTIwRWwlMjBlc3BhY2lvJTIwZGUlMjByYWNrJTIwdXRpbGl6YWJsZSUyMGRlcGVuZGVyJUMzJUExJTIwZGUlMjBsYXMlMjBvcGNpb25lcyUyMHNlbGVjY2lvbmFkYXMuJTIwQWRlbSVDMyVBMXMlMkMlMjBsYXMlMjBlbXByZXNhcyUyQyUyMGdyYW5kZXMlMjBvJTIwcGVxdWUlQzMlQjFhcyUyQyUyMHB1ZWRlbiUyMGVzY2FsYXIlMjBsYSUyMGNhcGFjaWRhZCUyMGRlbCUyMERhdGElMjBDZW50ZXIlMjBoYWNpYSUyMGFycmliYSUyMG8lMjBoYWNpYSUyMGFiYWpvJTIwcGFyYSUyMHNhdGlzZmFjZXIlMjBsYXMlMjBkZW1hbmRhcyUyMGZsdWN0dWFudGVzLg==” type=”h6″ class=”grayc”][margin margin_top=”40px”]
Una unidad construida específicamente con condiciones climáticas y eléctricas especiales para alojar equipo de cómputo y telecomunicaciones
[elements des=”JTNDaDUlM0UlMEElMDlSZXRhaWwlMjAlMEElM0MlMkZoNSUzRQ==” icon_awesome=”shopping-cart” class=”isecbox animated eff-fadeInUp”][margin margin_top=”40px”][elements des=”JTNDaDUlM0UlMEElMDlGaW5hbmNpZXJvJTBBJTNDJTJGaDUlM0U=” icon_awesome=”stack-overflow” class=”isecbox animated eff-fadeInUp delay-400ms”]
[elements des=”JTNDaDUlM0UlMEElMDlQZXRyb2xlbyUyQyUyMEdhcyUyMHklMjBNaW5lciVDMyVBRGElMEElM0MlMkZoNSUzRQ==” icon_awesome=”crop” class=”isecbox animated eff-fadeInUp” icon_simple_line=”fire”][margin margin_top=”40px”][elements des=”JTNDaDUlM0UlMEElMDlEQyUyMG9uJTIwRGVtYW5kJTJDJTIwSURDJTJDJTIwQ3VhcnRvJTIwZGUlMjBTZXJ2aWRvcmVzJTBBJTNDJTJGaDUlM0U=” icon_awesome=”tasks” class=”isecbox animated eff-fadeInUp delay-400ms”]


[titles text=”U1RVTFolMjBNaWNybyUyMERhdGElMjBDZW50ZXIlMjBDeWJlck1EQyUwQUVzY2FsYWJsZSUyMC0lMjBNb2R1bGFyJTIwLSUyMEVmaWNpZW50ZQ==” type=”h2″]
STULZ Micro DC proporciona una solución modular que permite desplegar rápidamente la capacidad de TI incluso en espacios limitados. Se puede configurar para carga TI de baja, mediana y mayor densidad. Con una combinación de aire de precisión y DCLC (Direct Contact Liquid Cooling)
- Adecuado para entornos sin Data Center
- Diseño modular con solución de enfriamiento integrada
- Escalable de baja a alta densidad
- Fácil instalación y expansión
- Configurado, probado y enviado desde MD,USA
[titles text=”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” type=”h2″ class=”caps”][margin margin_top=”40px”]
[titles text=”RGlzcG9uaWJsZSUyMGVuJTIwMyUyMGRpc2UlQzMlQjFvcyUyMGRlJTIwYXJtYXJpbyUyMGF1dG9jZXJyYWJsZQ==” type=”h2″]
[margin margin_top=”70px”]


UPS 10kVA
- Para equipo TI y el controlador CyberRow
- 8u altura de rack – UPS 10kVA, incl. módulo de batería
- 4u altura de rack – UPS de 6 kVA, incl. baterías
- Autonomía de 5 – 6 min para ambos UPS
- Modos de trabajos seleccionables
- Factor de potencia y eficiencia. Los más altos
- Posibilidad de conexión BMS

PDU
- PDU rack inteligente
- 30 x C13 socket
- 6 x C19 socket
- Integración de advertencias ambientales
- Monitoreo continuo de energía

MONITOREO AMBIENTAL
- 1 u Altura de Rack
- Supervisión de todos los sistemas incluidos sensores adicionales
- Fuente de alimentación dual y batería de respaldo integrada
- Visualización del CyberMDC
- Conexión BMS (Modbus, SNMP)

DETECCIÓN Y SUPRESIÓN DE FUEGO
- Novec 1230, FM200 y Argonite (3,0m³)
- 2u altura de rack
- Detección de punto 2x
- Tiempo de reacción -10 seg
- Conexiones remotas BMS